Panel dimming
The pull-down DIM output of the HDX can sink a maximum of 120mA
If this DIM output is used to control the brightness of the intercom and the compass light, the current budget is as follows:
The Precision PAI700 direct reading compass has a built in light (incandescent)


Stated current draw of the lamp is 65mA. The measured (the lamp unit is marked 14V) current draw 125mA
The SV-INTERCOM-2S DIM input functionality is

It is pretty clear that this input most probably connects to a series LED/resistor tied to the positive rail.
The measured current flowing to GND with the intercom powered up and LED energized is 9mA
Without further buffering it is not practical to drive the compass light directly from the DIM output. Instead I am going to couple the compass light to the overhead light system.
HDP20 pin assignments - part 2
This post is from Adam Dickson